logo

.
ECG
Cardiomin-2k
Cardiomin 2K
Cardiomin-2K
Features :
Simultaneously acquisition of 12-lead ECG data, IEC Class I, type CF safety standard.
High resolution thermal printing array system.
12-Lead ECG Waveforms display synchronously via larger LCD.
Selectable four modes of leads: Manual (standard single channel); Auto I (standard single channel), Auto II (standard single channel plus rhythm lead) and Auto III (standard two channel).
Measurement function under Auto Mode operation.
Filter for AC, EMG and DFT.
Hidden holder for easy carriage.
Function of heart rate detection and protection against possible pulse shock while
pacemaker applied.
Real time clock, heart rate examination
Option:
USB&RS232 interface & software(12-lead ECG waveform can be transferred to PC, measured, analyzed, stored or printed out on A4 paper)
Circuit Floating Protection against defibrillator effect
Lead Standard 12 leads
Patient Current Leakage <10μA
Input Impedance ≥100ΜΩ
Calibrating Voltage 1mV±3%
Digital Sampling 12 bits (simultaneously acquisition of 12 leads ECG data)
Frequency Response 0.05Hz~165Hz (-3dB)
Time Constant >3.2seconds
CMRR >100dB (with filter)
EMG Filter 40Hz (-3dB)
DFT Filter Automatic adjustment
Sensitivity 2.5, 5, 10, 20mm/mV ±3%
Paper Speed 6.25,12.5, 25, 50mm/s, ±3%
Recording Paper 50mm, 20m/30m, high-speed (roll/pile)
Input Circuit Current ≤50nA
Power Supply AC 85v-265v / 50/60Hz DC 12V, 1500mA (Built in rechargeable battery)
Depolarization Voltage ±450mV
Noise Level <15µVp-p
Dimension 288 x 209 x 62mm
Dimension (carton) 380 x280x200mm
Net Weight 2.75 Kgs
Weight 4.5Kgs
Accessories :
3 Channel ECG
3 Channel ECG
3 Channel ECG
Features :
Simultaneously acquisition of 12-lead ECG data, IEC Class I, type CF safety standard.
High resolution thermal printing array system.
12-Lead ECG Waveforms display synchronously via larger LCD.
Selectable four modes of leads: Manual (standard single channel); Auto I (standard single channel), Auto II (standard single channel plus rhythm lead) and Auto III (standard two channel).
Measurement function under Auto Mode operation.
Filter for AC, EMG and DFT.
Hidden holder for easy carriage.
Function of heart rate detection and protection against possible pulse shock while pacemaker applied.
Real time clock, heart rate examination
Option :
USB&RS232 interface & software(12-lead ECG waveform can be transferred to
PC, measured, analyzed, stored or printed out on A4 paper)
Circuit Floating Protection against defibrillator effect
Lead Standard 12 leads
Patient Current Leakage <10μA
Input Impedance ≥100ΜΩ
Calibrating Voltage 1mV±3%
Digital Sampling 12 bits (simultaneously acquisition of 12 leads ECG data)
Frequency Response 0.05Hz~165Hz (-3dB)
Time Constant >3.2seconds
CMRR >100dB (with filter)
EMG Filter 40Hz (-3dB)
DFT Filter Automatic adjustment
Sensitivity 2.5, 5, 10, 20mm/mV ±3%
Paper Speed 6.25,12.5, 25, 50mm/s, ±3%
Recording Paper 50mm, 20m/30m, high-speed (roll/pile)
Input Circuit Current ≤50nA
Power Supply AC 85v-265v / 50/60Hz DC 12V, 1500mA (Built in rechargeable battery)
Depolarization Voltage ±450mV
Noise Level <15µVp-p
Dimension 288 x 209 x 62mm
Dimension (carton) 380 x280x200mm
Net Weight 2.75 Kgs
Weight 4.5Kgs
Accessories :

Cardiomin-3c
Cardiomin 3c
Cardiomin-3c
Features :
Three Channel Display and Print Out
Wide screen with Uncompressed waveform Display.
Automatic adjustment of baseline, amplification and lead switching
Digital wave filter to eliminate baseline drift, AC & EMG interference
Built in rechargeable Li-ion battery, Support 2 hours uninterrupted operation
Multiple printout modes like Running Traces, Average Report, rythm lead, measurement and diagnosis.
60 Electrocardiogram record and recall, with memory expansion capacity.
Accurate Lead OFF detection & Display.
Supports rich patient information input.
Optional Networking Capability.
Note: Due to continuous research and development the illustrations and specifications are subject to modifications, without notice.
.

Copyright ©, Taurus Medical Corporation, Ghaziabad Site Developed by Sabisa Info Technology