logo

.
ETCO2 Monitor
Specifications
Sidestream Technology using Welch Allyn
Measurement of etCO2, iCO2 & Respiration
Useful for Intubated & Non-intubated patients
Apnea Alarm - Settings of 10, 20 & 30 sec. delay
Alarm for Limit Violations & Apnea
BTPS Correction, O2 / N2O Compensation
3 Averaging Methods - Breath - Breath, 4 & 8 Breath
Taurus ETCO2 Monitor
ETCO2 Monitor
3 Measurement Units -mmHg. % Vol., KPa
3 Waveform Speeds - 3.12, 6.25 & 12.5 mm/sec
Different Flow Rates for Adults (175 ml / min ) & Neonate (90 ml / min)
Trends for 144 hours with scrolling
Waveform Freeze with scrolling upto 60 secs
Waveform Line & Fill options
Built-in Rechargeable Battery Back-up of 3 hours
Power Saving Mode - Backlight Timer & Off
Reversible Background - Light & Dark
Low Battery Audio & Visual Alarm
Trends available on Dot-Matrix Parallel Printer
Ideally suited for Laparoscopy, Neuro OT, Gen. OT, ICU, ICCU, NICU, PICU

Technical Specification
Displays,Indicators & Keys ETCO2 (End Tidal CO2)
Red LED Display 0.4”
ETCO2

Amber LED Display 0.4”
Respiration Rate

LED Display
240x64 pixels, STN, Transmissive, Negative, White LED Backlight, Viewing Area 132.6x39.0mm Display of Capnogram, iCO2, & Alarm Limits

Red LED 3mm
Battery

Green LED 3mm
Charging

Keys
On/Off, Menu/Standby, Up, Down, Cancel, Waveform/Trend, Freeze, Silence
ETCO2 (End Tidal CO2)
Built-in Sidestream Sensor

Sampling Method
Non-dispersive, Infrare, Single Beam

Principle of Operation 0 to 99 mmHg ( 0 to 13.0 %Vol, 0 to 13.2 KPa)

Range (iCO2) 0 to 25 mmHg ( 0 to 3.3 %Vol, 0 to 3.3 KPa)

Accuracy(etCO2) +3mmHg 00to40mmHg Range +8% of reading 41 to 76 mmHg Range +10% of reading 77 to 99 mmHg Range

Averaging Breath-to-Breath, 4 Breaths, 8 Breaths Flow Rate 175 ml/min (Adult), 90 ml/min (Neonate)

Flow Rate Accuracy +15%, -20% of Set Value

Calibration
Zero Calibration & Two Point Gas Celibration

Startup Time Less than 10 sec. to acquire CO2 Waveform data.

C-Cap Rise Time Less then 200 mS (10% - 90% Bench Only)
Capnogram Respiration Rate
Wave Speed
Display type
Wave Freeze

3,12,6.25,12.5 mm/sec
Line or Fill
Scrolling available for previous 5 Screens
Range
1 to 99 breaths per minute

Accuracy
+1 bmp

Resolution
1 bmp
Apnea Alarms
Delay of 10, 20 & 30 secs. Limit Violation, Apnea, Various System Failures
Silence Alarm Ranges
2 min Silence & Permanent Silence ETCO2(mmHg)
iCO2(mmHg)
Respiration (bpm)
1 to 99
1 to 25
5 to 100
0 to 98
0 to 24
0 to 95
Memory Trends (Available on Display & Printing) Printing (Available on any Parallel Printer)
Past Trends of etCO2, iCO2 & Respiration Rate for 144 hours (6 days)
Trends available on Display - 15min, 1hr, 2hrs, 4hrs & 8hrs Past
Trends of 144 hours (6 days)
Real Time (etCO2 & Respiraton Rate) at 1 min, intervals
Past Trends of 144 hours (6 days)
Power Requirement Dimensions
Battery Charging Time
Battery Backup
AC Mains
Rechargeable Built-in Sealed Lead Acid Battery
8 hours
3 hours
230 Vac, 50Hz
Width 10.20” (260mm)
Height 3.85” (98mm)
Depth 6.70” (170mm)
Environmental Specifications
Temperature: 5 to 55 deg. C (Operating), -40 to 70 deg. C(Storage)
Relative Humidity :15 to 95% (Operating), 10 to 100% (Stroge) Nont-cond.
Barometric Pressure : 420-795 mmHg (Operating), 375-795 mmHg ( Storage)
.