logo

.
Multipara Monitor-Sure Signs/Vital Signs
Specification
In-hospital applications include emergency, pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and hospital-based special procedure areas.
Advanced streamline outline design, compact, lightweight, in-built handle makes it truly portable
Can be used to monitor adult, pediatric & neonate patient
Upto eight wave-channel display
In-built Rechargeable battery which provides a good backup lime
96 Hours graphical and tabular trends memory
With function of arrhythmia analysis, drug dose calculation, pacemaker detection and ST segment analysis.
MultiPara Patient Monitor
Multipara Monitor-Sure Signs
User friendly menu structure with easy to use rotary dial
Protection Against electro surgical interference and defibrillation
Intelligent audio and visual comprehensive alarm. Volume adjustment possible
Central monitoring system for long-distance monitoring, diagnosis, maintenance and software upgrade possible
MultiPara Monitor
Multipara Monitor-Vital Signs
Standard Configuration : ECG, HR, Sp02' ST Analysis, Resp, NIBP, Temp, Drug Dose Calculation, built in battery
Optional Configuration: Recorder, 2*IBP, CO2
Technical Specifications:
ECG Temperature (Skin or Intra-Cavity)
Input: 5 wires/3 wires ECG cable
Lead selection: I,II,III, aVR, aVL, aVF, V Gain (mm/mV) : 1/4,1/2, 1, 2, 4 & auto
Frequency response: Diagnosis 0.05 - 100Hz Monitor 0.5 - 40 Hz Surgery 1.0 - 25 Hz
Sweep speed (mm/sec) : 12.5, 25, 50
Heart rate range: 10-300 BPM
Heart rate accuracy: ± 1 % or ± 1 BPM, which is greater
ST segment deviation analysis: -0.8 - +0.8mV
ST accuracy: ±0.02mV
Heart Rate Alarm: Yes
Measurement range: 0~500C Accuracy: ± 0.10C Resolution: 0.10C Response time: < 3 min.
Channel: 1 Channel
Respiration Rate (RA-LL Impedance) ETC02 (Optional Side Stream Type)
Measurement range: 0 - 120 BPM
Accuracy: ± 2 BPM
Resolution: 1 BPM
Measurement range: 0%-13.1 % (0~99mmHg)
Accuracy: ± 0.3%(< 5% Measurement value) <10% (> 5% Measurement value)
Response Time: 180 ms
Non-Invasive Blood Pressure(Oscillographic) 2·lnvasive Blood Pressure (Optional)
Measurement type: adult, pediatric, neonate Measurement range: Systolic 30~270mmHg Diastolic 10~220mmHg Mean 20~235mmHg Accuracy: ± 2% or ± 3mmHg, which is greater Resolution: 1 mmHg Protection: over pressure Measurement range: -45~+300mmHg Channel: 2 channel
Transducer sensitivity: 5uV/V/mmHg, 2%
Unit display: kPa or mmHg selectable
Pulse Oximetry Environment
SpO2 measurement range: 0 -100 % Resolution: 1 % Pulse measurement range: 25- 250BPM Accuracy: ± 2 %. 70~100% Resolution: 1 BPM Operation Storage Temperature 0- 40·C -20 - 500C Relative humidity < 85% < 93%
Physical Electrical
Weight: ~ 4.5 Kg Size: 318mm x 264mm x 152mm Input: 100~240 V AC, 50/60Hz Consumption: < 70VA Battery type: Lead-Acid Battery Operation: ~ 2 hrs
OxyCRG Diagram Big Digit Display
Enables the doctor to relate information of patient rapidly & accurately by displaying HR, RESP and oxygen parameter on same screen Big digit display format makes reading parameters from a distance easy
Simultaneous Seven leads ECG display
Multipara Patient Monitor
TMC-Krober 15" LCD Display
.

Copyright ©, Taurus Medical Corporation, Ghaziabad Site Developed by Sabisa Info Technology